● Features of A-TJ high speed low nitrogen burner
The furnace structure is simplified, and there is no need for a spacious combustion chamber in addition to the fire passage.
1. The high temperature flue gas sprayed at high speed can eject a large amount of low temperature flue gas in the furnace, forming strong flue gas reflux and mixing action, so that the temperature distribution in the furnace is uniform.
2. The regulating ratio is large, and the heat transfer is mainly by convection, so that the temperature in the furnace can be high or low and the thermal inertia is small, and the use range of the furnace is expanded.
3. Suppress NOx formation. By controlling the oxygen concentration to the minimum required during combustion, the flue gas stays in the high-temperature zone for a short time. The high-temperature and high-speed flue gas is drawn into the furnace by the lower temperature flue gas, which is rapidly diluted and cooled. The intense heat exchange within the furnace also quickly reduces the flue gas temperature, thereby suppressing NOx formation.
4, save fuel, high combustion efficiency.
5. Various fire channel structures (burner brick, ceramic silicon carbide, metal combustion chamber) can be selected according to the actual situation.
● apply
Steelmoving heating furnace, stepping heating furnace, bottom-kun tempering furnace, ring heating furnace, stainless steel strip continuous annealing furnace, trolley heating furnace, chamber heating furnace heat treatment furnace
● Ignition and flame monitoring
The burner ignition can be achieved by the ignition electrode.
Flame detection can be selected with ion electrodes and UV external lines.
When the burner is used in a furnace temperature below 750 C, it is recommended to install a fire detection system.
Product Parameter | |
Air shell: | Cast iron HT250 |
Air inlet flange material: | Cast iron HT250 |
Maximum furnace temperature applied: | 1500℃ |
Fire tube material: | SUS 310S/SIC |
Burner head material: | SUS 310S |
Fixed flange: | Cast iron HT250 |
Maximum preheating air temperature: | 350℃ |
Power range: | 40-528KW |
Air inlet pressure: | 30-50mbar |
Gas inlet pressure: | 10-50mbar |
Fuel: | NG/LPG/COG |
Ratio of adjustment: | 1:20 |
Speed selection: | Medium speed/high speed |
Exhaust outlet speed: | 125-230m/s |
Gas Solenoid valve
Wind/Air Actuator valve
Manual gas and wind valve
Gas air propotional Valve
Gas regulator pressure valve
Flame detection and burner ignition controllers
Blowers
Accessories