Product presentation: AVE20N Fast open solenoid valve is a kind of automatic valve of quickly opening and closing by electromagnetic force, widely used in industrial automation control system, used to control the flow of liquid, gas and other media. It is characterized by rapid response, reliable action, suitable for the need to quickly switch occasions.
This gas solenoid valve can be widely used in the field of gas safety transmission control to provide open or emergency cut gas supply. Can be applied to gas media, such as: natural gas, methane, liquefied petroleum gas, etc.
Operation and installation:
Normally closed type, power on quickly open, on the green light on, off the power, the light off. Both sides of the valve body are equipped with bypass holes of G1 / 4"
Notes for the installation and use of the gas solenoid valve:
1, The installation should choose the horizontal pipe section with small vibration, DN50 allowed below 90 degrees above DN65 only allowed horizontal installation.
2. The parameters on the solenoid valve nameplate should comply with the actual use requirements
3. The arrow on the solenoid valve body should be consistent with the flow direction of the medium.
4. In order to ensure the normal use of the solenoid valve, please install a special gas filter in front of the valve.
5, The valve itself does not have explosion-proof performance
6. Before installation, please thoroughly purge the pipe to avoid the failure of the solenoid valve caused by foreign body diaphragm
7, Such as installed in the outdoor and harsh environment should do the corresponding effective protection
8, When the solenoid valve failure, in order to timely isolation and facilitate repair, it is recommended to install a bypass and pass device
9. If the valve starts and closes failure during use, check whether the coil is powered off; whether the power supply and medium pressure is normal
10. When the solenoid valve is not installed temporarily, it can be stored in the ambient temperature 0-40℃, relative humidity
Product Parameter | |
Open and dose time: | <1 second |
Maximum working frequency: | 20 times per minute |
Maximum working pressure: | DN15-50 200 mbar with G1 /4 aperture bypass hole internaI filter |
Protection level: | IP54 |
Sealing material: | Nitrile rubber |
Ambient temperature: | -15°C--60°C |
Coil temperature: | 65°C |
Rated voltage: | 50/60Hz,230 Vac coil grade F,360 rotation,100% long-term |